Flashtube replacement

Most Elinchrom flash heads have plug-in flashtubes, making it easy to change flashtube yourself.

  1. Switch the unit OFF
  2. Remove the mains cable
  3. Take the unit from its stand and lay it horizontally on a rigid surface.
    It will need to be held firmly whilst removing and replacing the flashtube.
  4. Allow the flashtube and modeling lamp to cool down and wait for the unit to discharge for 30 minutes.
  5. Carefully remove and store the modeling lamp. They can be very hot.
  6. Pull the flashtube firmly out of the terminals.
    If the tube is broken, use security gloves to avoid cutting yourself and use an insulated tool to pull out the electrodes.
  7. Never touch the metal electrodes and ensure that the unit has been disconnected from the mains for 30 minutes.
  8. Take the new flashtube.
    Insulated tissues or security gloves MUST BE USED.
    Any contact with your fingers on the tube can cause dark markings on the tube when used.
  9. Check that the tube is correctly aligned (central) and that the trigger contact is gripping the tube.
  10. Re-connect and test the unit as usual.
    Always use a protective glove to remove the flashtube.